fwts: handle corrupt ACPI tables input

Bug #1281197 reported by Colin Ian King
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Firmware Test Suite
Fix Released
High
Colin Ian King

Bug Description

A corrupt ACPI table input (as generated from acpidump or fwts --dump) with zero data will cause fwts to segfault when trying parse the data. The fix is to ignore any more data parsing for that table if there are no hex digits found on a line, even if the table address offset looks legitimate.

Changed in fwts:
status: New → In Progress
importance: Undecided → Medium
assignee: nobody → Colin King (colin-king)
importance: Medium → High
Revision history for this message
Colin Ian King (colin-king) wrote :
Changed in fwts:
milestone: none → 14.02.00
Alex Hung (alexhung)
Changed in fwts:
status: In Progress → Fix Released
To post a comment you must log in.
This report contains Public information  
Everyone can see this information.

Other bug subscribers

Remote bug watches

Bug watches keep track of this bug in other bug trackers.