[regression] surface remains invisible when changing from state minimized/hidden to any other

Bug #1483909 reported by Alberto Aguirre
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
Mir
Fix Released
Medium
Alberto Aguirre
mir (Ubuntu)
Fix Released
Medium
Unassigned

Bug Description

With mir_demo_server, the surface remains invisible when client does:

mir_wait_for(mir_surface_set_state(surface, mir_surface_state_hidden)); //or mir_surface_state_minimized
mir_wait_for(mir_surface_set_state(surface, mir_surface_state_restored)); //Or any of the other states where the surface is visible.

Tags: regression

Related branches

description: updated
summary: - surface remains invisible when changing from state minimized/hidden to
- any other
+ [regression] surface remains invisible when changing from state
+ minimized/hidden to any other
tags: added: regression
Changed in mir:
status: In Progress → Fix Committed
Changed in mir:
status: Fix Committed → Fix Released
Revision history for this message
Daniel van Vugt (vanvugt) wrote :

mir (0.16.0+15.10.20150921.1-0ubuntu1) wily; urgency=medium

Changed in mir (Ubuntu):
importance: Undecided → Medium
status: New → Fix Released
To post a comment you must log in.