More than 1 global bus between sheets

Bug #1545708 reported by Dieter Kunkel
6
This bug affects 1 person
Affects Status Importance Assigned to Milestone
KiCad
Fix Released
High
jean-pierre charras

Bug Description

My project consists of 2 sheets. The Main Sheet and one hierarchical sheet.

One global bus between these sheets (e.g. AD[0..7]) works fine.
But if I add a second global bus (e.g. AP[0..15]), there is no connection between the buses of each sheet in the netlist.

I had to change the second bus to a 'local bus' in the hierarchical sheet and import it to the main sheet.

Related branches

Revision history for this message
jean-pierre charras (jp-charras) wrote :

Please:
- Gives the Kicad version.
- Send us your not working project.
Thanks.

Changed in kicad:
status: New → Incomplete
Revision history for this message
Wayne Stambaugh (stambaughw) wrote :

He is probably using a nightly build. Over the weekend, I discovered an issue with complex hierarchy net lists that I created with my Eeschema refactoring. I'm still working on it.

Changed in kicad:
assignee: nobody → Wayne Stambaugh (stambaughw)
importance: Undecided → High
Revision history for this message
Dieter Kunkel (dieter-kunkel) wrote : Aw: [Bug 1545708] Re: More than 1 global bus between sheets
Revision history for this message
Dieter Kunkel (dieter-kunkel) wrote :
Revision history for this message
jean-pierre charras (jp-charras) wrote :

Global bus labels just not work.
Members are not seen as global.
They just do not work in all Kicad versions (even in 2013 stable version).
Currently, until the bug is fixed, they cannot be used.

Changed in kicad:
status: Incomplete → Fix Committed
assignee: Wayne Stambaugh (stambaughw) → jean-pierre charras (jp-charras)
Changed in kicad:
status: Fix Committed → Fix Released
To post a comment you must log in.